Sectional Body Series "20" - 20 GPM - 3000 PSI - Load Checks Standard: Standard Inlet Sections

Standard Inlet Sections
Part Number Relief Type & Setting Port Size
20I2A No Relief #12 SAE ORB
20I2C Shim Adjustable 1351-1750 PSI, Set at 1750 PSI @ 10 GPM #12 SAE ORB
20I2D Shim Adjustable 1751-2200 PSI, Set at 2200 PSI @ 10 GPM #12 SAE ORB
20I2E Shim Adjustable 2201-3000 PSI, Set at 2500 PSI @ 10 GPM #12 SAE ORB
20I2G Adjustable 1351-1750 PSI, Set at 1750 PSI @ 10 GPM #12 SAE ORB
20I2H Adjustable 1751-2200 PSI, Set at 2200 PSI @ 10 GPM #12 SAE ORB
20I2J Adjustable 2201-3000 PSI, Set at 2500 PSI @ 10 GPM #12 SAE ORB

Features

  • 1 - 10 Work Sections
  • Extra Fine Spool Metering
  • Power Beyond Capability
  • Reversible Handle
  • Load Checks on Each Work Port
  • Hard Chrome Plated Spools
  • A Float Section can be Installed in any Location in Valve Assembly
  • Interchangeable Mounting With Other Popular "20" gpm Stack Valves
  • Optional Work Section with Pilot Operated Checks

Specifications

  • Parallel or Tandem Circuit Foot Mounting
  • Maximum Operating Pressure - 3500 psi
  • Inlet Cover - Approx 6 lbs
  • Maximum Tank Pressure - 500 psi
  • Outlet Cover - Approx 3.5 lbs
  • Work Section - Approx 9 lbs
  • Nominal Flow Rating - 20 gpm
  • Maximum Operating Temp - 180 degrees F
  • Please refer to pressure drop charts. Allowable pressure loss thru valve determines the maximum flow.

See PDF for complete specifications